Skip to content

Existing Customers Call 626-359-4550 Or Visit Customer Care

Vietnam Electricity Gains 39.6 MW Boost

Vietnam Electricity installed MeeFog systems on two Siemens V94.2 gas turbines. The systems provide evaporative cooling and wet compression and produce a 19.7 MW power boost, resulting in a 39.6 MW total power boost for the plant. Wet compression consists of spraying water into the gas turbine compressor. The water evaporates inside the compressor. This inter-cooling effect reduces the work of compression, which causes an increase in power output.

Project Conditions:

Location: PhuMy 2.1 Extension, Vietnam
Hot day conditions: 38° with 27° C wet bulb
Elevation: Sea level
Max power boost per GT: 19.8 MW
Mee’s scope of work: Supply of fog pump skids, nozzle manifolds, and supervision of installation and commissioning

Fog System Design:

Evaporative cooling and 0.6% (for the airmass flow) as wet compression
Cooling stages: 16
Operating pressure: 2,000 psi
Fog droplet size: 12 microns
Nozzle flow rate: 0.17 lpm per nozzle
MeeFog™ nozzle count: 2,048
Max power requirement: 160 HP

Learn More

Want to learn more about successful Meefog systems installation projects and case studies?

Other Related Blog Articles

Watson Cogeneration Boosts Output by 10 MW with MeeFog Wet Compression System

Case Study: Learn how Watson Cogeneration increased power production by 10 MW using MeeFog’s advanced wet comp...

MeeFog Adds 64MW of Power Augmentation to Mexican Power Plant

Case Study: To capitalize on new market opportunities arising from energy regulations in Mexico, the Tuxpan III......

Boost of 28 MW on two Siemens SGT-5000FD2 GTs Using Wet Compression

Project Profile: MeeFog wet compression systems fitted onto two Siemens SGT-5000FD2 gas turbines in the state of......