Skip to content

Existing Customers Call 626-359-4550 Or Visit Customer Care

Victoria Texas 501F Generates 24 MW Boost M501F GT

  • Blue gradient city outlined in white to show wet compression for gas turbines

Gas Turbine Inlet Air Fogging – Victoria, Texas

The MeeFog system provides wet compression downstream of an existing evaporative cooler for the M501F gas turbine. The Meefog skid has six pumps and provides six stages of fogging. Each stage produces a 4 MW power boost, resulting in a 24 MW total power boost.

Project Conditions:

Location: Victoria, Texas
Model: M501F Gas Turbine
Hot day conditions: 97° F with 76° wet bulb
Elevation: 118 feet
Mee’s scope of work: Turnkey, excluding control mods

Fog System Design:

Cooling Stages: 6
Operating Pressure: 2,000 psi
Fog Droplet Size: 12 microns (D32)
MeeFog™ Nozzle Count: 1,950
Nozzle Flow Rate: 0.080 gpm per nozzle
Max. Skid Water Flow: 156 gpm
Max. Power Requirement: 6 x 50 HP

Learn More

Want to learn more about successful Meefog systems installation projects and case studies?

Other Related Blog Articles

Exterior of Watson Cogeneration Plant (WCP) during sunset

Watson Cogeneration Boosts Output by 10 MW with MeeFog Wet Compression System

Case Study: Learn how Watson Cogeneration increased power production by 10 MW using MeeFog’s advanced wet comp...

MeeFog Adds 64MW of Power Augmentation to Mexican Power Plant

Case Study: To capitalize on new market opportunities arising from energy regulations in Mexico, the Tuxpan III......

Boost of 28 MW on two Siemens SGT-5000FD2 GTs Using Wet Compression

Project Profile: MeeFog wet compression systems fitted onto two Siemens SGT-5000FD2 gas turbines in the state of......